Category:Vrije Universiteit Brussel Project



1.Search Strategy

2.Definition/Description

3.Clinically Relevant Anatomy

4.Epidemiology /Etiology

5.Characteristics/Clinical Presentation

6.Differential Diagnosis

7.Diagnostic Procedures

8.Outcome Measures

9.Examination

10.Medical Management

11.Physical Therapy Management

12.Key Evidence

13.Resources

14.Clinical Bottom Line

15.Recent Related Research (from Pubmed)

16.References


1.Search Strategy

I used pedro, Pubmed, google scholar. In those database I systematically search with the keywords; Pulley A2, Pulley A4, Pulley ruptures, physiotherapy pulley rupture, climbing injury, ...


2.Definition/ Description

For a maximal efficiency of joint rotation in the hand, there are some pulleys; the transversal carpal ligament, the palmar aponeurosis and some pulleys along the digits. Those pulleys consist in five annular and 3 cruciform pulleys. [1]


3.Clinical Relevant Anatomy

The most important oneʼs are the A2 and the A4 pulleys [2], situated at the palmar side of the digits. The A2 pulley is continuous with the periosteum of the proximal phalanx and the A4 pulley is in the middle of the middle phalanx.
Bron 1
The annular pulleys are optimised for the purpose of flexor tendon positioning and gliding. In the A2 pulley there were identified 3 layers [3]. In the outmost layer is a loosely arranged areolar tissue contain fine capillary network. Itʼs also continue with the synovial membrane that provides nutrient vascular supplies to the pulley. The middle layer of the pulley is densely arranged with collagen bundles, those are oriented perpendicular to the long axis of the flexor tendon. This optimised the resistance of the pulley.
The innermost layer, correspond to the gliding surface of the pulley. It is composed of collagen bundles, oriented parallel with the flexor tendon. That optimised the gliding between the flexor tendon en the pulley. Within this layer, elongated elastin fibrils were regularly positioned within the collagen fiber array [4].


4.Epidemiology /Etiology


5.Characteristics/Clinical Presentation 6.Differential Diagnosis 7.Outcome Measures 8.Diagnostic Procedures

A fresh pulley injury results in a local swelling, tenderness and pain over the affected area. The main indicator to identifyif a total rupture of a pulley has occurred is the appearance of the clinical bowstringing (In this case; when the finger is in flexion, the flexor tendon is taking the shortest line between the top and the base of the finger. Instead of following the phalang).
Bron 2 This method is very conclusive, but you can only use it with a total rupture of the pulley [29]. The most recent study I found about the diagnostic procedure of the pulley, was a comparison between the effectiveness of ultrasonography and MRI (Magnetic Resonance Imaging) scanning. This study showed us that the ultrasonography is a better diagnostic tool than the MRI. Not only because itʼs an inexpensive method but also because you can have more precision and a better view with the ultrasonography [5].


9.Examination

There are 3 grades in the pulley injury: Grade III: "Complete rupture of the pulley causing bowstring of the tendon. Symptoms " are: " locally pain at the pulley, heard a PO or CRACK, swelling, pain when " squeezing or climbing, pain while finger extension GradeII:" Partialruptureofthepulley.Symptoms:locallypainatthepulley,painwhile " extending finger and while climbing GradeI:" Spraininthefingerligament.Symptoms:Locallypain,painwhensqueezing " or climbing


10.Medical Management

Tension of the grafts was evaluated to have an idea of the tension that is recommended in a new graft. The tension of an healthy pulley is between 0,49N and 1,69N. On the bases of those findings we recommend that reconstructed pulley be tensioned to approximately 1N [6].
Free extrasynovial tendon grafts are the most commune method currently in use for pulley reconstruction.
The A2 and A4 are recommended to be reconstructed using multiple loops of free extrasynovial tendon grafts on the same place were the original digital pulley was [7].
The strength of the repaired pulley is correlated with the number of loops in the tendon [8]. But recent studies suggest that intersynovial donor tendons may be more efficient as free extrasynovial tendon graft [9]. The intersynovial grafts had less frictions, what gives a better mobility in the digits.
An other method report on the use of the dorsal wrist retinaculum for the reconstruction of the annular digital pulleys [10]. About 8 cm. of the retinaculum is necessary for the reconstruction of each digital pulley. It is recommended that the under surface of the extensor retinaculum is orientated toward the tendon for a better gliding. An independent biomechanical assessment of this pulley reconstruction concluded that this method gives a limitation in the mechanical effectiveness.
The ever present Rim, is a tendon weave technique that is based on the remnant of the ruptured pulley. The advantage of this technique is that the long pulley structure retains the flexor tendon in close proximity to the bone. Itʼs a very efficient technique but itʼs also shown to be one of the weakest pulley reconstruction methods [11].


11.Physical Therapy Management

Rohrbough indicates that there remains some disagreement between researchers as to the treatment of pulley tears [15].
Stretching is recognized as an important promoter of formation of strong compacted scar tissue[16]. Stretching involves pulling the finger in the varus direction, effectively hyper
extending the metacarpophlangeal joint and PIP joint [17]. An alternative therapy such a squeezing a ball may be useful. Such therapy is useful in
promoting healing in the injury, it does not prevent atrophy of other healthy tissues [14].
Minor A2 pulley injuries or partial tears with no evidence of bowstringing can be treated with either firm circumferential taping for 2 to 3 months to permit healing [13]. The effectiveness of pulley taping was tested [18]. The effect was maximized (10% of bowstringing force) when the tape is positioned near the distal end of the proximal phalanx. The tape absorbed progressively less bowstringing force as the force produced at the fingertip increased [18]. Non stretch, zinc oxide tape of 1.3 cm width was used [13]. This result has two implications. Firstly, taping is likely to be most effective during the earlier stages of rehabilitation when the forces produced by the fingers are lower. Secondly, taping is unlikely to prevent pulley injuries, as these are likely to occur when forces on the pulley are maximal [19].


12.Key Research

Digital Flexor Sheath: Repair and Reconstruction of the Annular Pulleys and Membranous Sheath
Analysis of the gliding pattern of the canine flexor digitorum profundus tendon through the A2 pulley, Shigeharu Uchiyama1, Peter C. Amadio, Lawrence J. Berglund, Kai-Nan An!
Biomechanics Laboratory, Division of Orthopedic Research, Mayo Clinic, 200 First Street S.W., Rochester, MN 55905, USA Accepted 15 January 2008
Zone II Combined Flexor Digitorum Superficialis and Flexor Digitorum Profundus Repair Distal to the A2 Pulley Jeffrey M. Pike, MD, Richard H. Gelberman, MD


13.Resources

Medscape Pubmed


14.Clinical Bottom Line


15.Recent Related Research (from Pubmed)


16.References


1. Kaplan EB: Functional andSurgical Anatomy of the Hand. Philadelphia, JB Lippincott Co, 2nd Ed, 1965
2. Lin GT, Amadic PC, An KN, et al: Functional anatomy of the human digital flexor pulley system. J Hand Surg Am 14:949-956, 1989
3. Cohen MJ, Kaplan L: Histology and ultrastructure of the human flexor tendon sheath. J Hand Surg Am 12:25-29, 1987 Level of evidence C
4. Katzman BM, Klein DM, Garven TC, et al: Anatomy and histology of the A5 pulley. J Hand Surg Am 23:653-657, 1998
5. Martinoli, C., Bianchi, S., Nebolio, M., Derchi, L. E., Garcia, J. F. (2000) Sonographic evaluation of digital annular pulley tears. Skeletal Radiol. 29: 387-391 Level of evidence: 2
6. Seiler JG, Uchiyama S, Ellis F, et al: Reconstruction of the flexor pulley. the effect of tension and source of the graft in an in vitro dog model. J Bone Joint Surg Am 80:699-703, 1998 Level of evidence: A2
7. Bunnell S: Repair of tendons in the fingers and descriptions of two new instruments. Surg Gynecol Obstet 26:103-110, 1918 Level of evidence: B
8. Widstrom CJ, Doyle JR, Johnson G: A mechanical study of the effectiveness of 6 digital pulley reconstruction techniques: Part 2. Strength of individual reconstructions. J Hand Surg Am 4:826-829,1989 Level of evidence: B
9. Nishida J, Amadio PC, Bettinger PC, et al: Excursion properties of tendon graft sources: interaction between tendon and A2 pulley. J Hand Surg Am 23:274-278, 1998 Level of evidence: C
10.Lister GD: Reconstruction of pulleys employing extensor retinaculum. J Hand Surg Am 4:461-464, 1979 Level of evidence: C
11.Kleinert HE, Bennett JB: Digital pulley reconstruction employing the always present rim of the other previous pulley. J Hand Surg Am 3:297-298, 1978 Level of evidence:C
12.Bowstring injury of the flexor tendon pulley system: MR imaging. Parellada JA, Balkissoon AR, Hayes CW, Conway WF. Source Department of Radiology, Medical College of Virginia, Virginia Commonwealth University, Richmond 23298, USA.31 Level of evidence: B
13.Hand Injuries in Rock Climbing: Reaching the Right Treatment Peter J. L. Jebson, MD; Curtis M. Steyers, MD THE PHYSICIAN AND SPORTSMEDICINE - VOL 25 - NO. 5 - MAY 97 Level of evidence B
14.A2 PULLEY INJURIES REVIEW RE-POSTED, TUESDAY, 4 MAY 2010 Dave macleod 15.Rohrbough, J. T., Mudge, M. K., Schilling, R. C. (2000) Overuse injuries in the elite rock
climber. Med. Sci Sports Exerc. 32(8): 1369-1372 Level of evidence B 16.Gailey, R. S., Raya, M. A. (2001) Manual Modalities. in: Gonzalez, E. G., Myers, S. J.,
Edelstein, J. E., Lieberman, J. S., Downey, J. A. Physiological basis of rehabilitation
medicine. 3rd ed. Butterworth Heinemann Level of evidence: 17.Gresham, N. (1996) High performance: warming up. High. 166: 14-15 Level of
evidence D
18.Schweizer, A. (2000) Biomechanical effectiveness of taping the A2 pulley in rock climbers. J. Hand Surg. 25B: 102-107 Level of evidence
19.Warme, W. J., Brooks, D. (2000) The Effect of circumferential taping on flexor tendon pulley failure in rock climbers. Am. J. Sports Med. 28(5): 674-678 Level of evidence:
Digital Flexor Sheath: Repair and Reconstruction of the Annular Pulleys and Membranous Sheath
Analysis of the gliding pattern of the canine flexor digitorum profundus tendon through the A2 pulley, Shigeharu Uchiyama1, Peter C. Amadio, Lawrence J. Berglund, Kai-Nan An!
Biomechanics Laboratory, Division of Orthopedic Research, Mayo Clinic, 200 First Street S.W., Rochester, MN 55905, USA Accepted 15 January 2008
Zone II Combined Flexor Digitorum Superficialis and Flexor Digitorum Profundus Repair Distal to the A2 Pulley Jeffrey M. Pike, MD, Richard H. Gelberman, MD
Bron 1: http://www.orthobullets.com/hand/6004/flexor-pulley-system Bron 2: http://edgar.brand.edgar-online.com/EFX_dll/EDGARpro.dll?FetchFilingHTML1? ID=5479903&SessionID=cg7xWq-zAf69x47

Pages in category "Vrije Universiteit Brussel Project"

The following 179 pages are in this category, out of 179 total.