Manual Hyperinflation: Difference between revisions
m (added video) |
m (references) |
||
Line 1: | Line 1: | ||
=== '''Introduction''' === | === '''Introduction''' === | ||
[[File:1-s2.0-S0031940612000557-gr2.jpg|thumb|Manual Resuscitator Bag used for Manual Hyperinflation or "bagging"]] | [[File:1-s2.0-S0031940612000557-gr2.jpg|thumb|Manual Resuscitator Bag used for Manual Hyperinflation or "bagging"]] | ||
Manual hyperinflation also known as manual ventilation or ‘bagging’, is a technique used by respiratory physiotherapists in the management of ventilated patients or patients self-ventilating through a tracheostomy. Manual hyperinflation is used to increase lung volumes and aid secretion clearance when used in conjunction with [[suctioning]]<ref name=":0">Volpe, M. S., Naves, J. M., Ribeiro, G. G., Ruas, G., &amp; Tucci, M. R. (2018). Effects of manual | Manual hyperinflation also known as manual ventilation or ‘bagging’, is a technique used by respiratory physiotherapists in the management of ventilated patients or patients self-ventilating through a tracheostomy. Manual hyperinflation is used to increase lung volumes and aid secretion clearance when used in conjunction with [[suctioning]]<ref name=":0">Volpe, M. S., Naves, J. M., Ribeiro, G. G., Ruas, G., &amp; Tucci, M. R. (2018). Effects of manual | ||
hyperinflation, clinical practice versus expert recommendation, on displacement of mucus | hyperinflation, clinical practice versus expert recommendation, on displacement of mucus | ||
simulant: A laboratory study. PLoS ONE, 13(2), 1–11. | simulant: A laboratory study. PLoS ONE, 13(2), 1–11. | ||
</ref>. Manual hyperinflation involves the use of a manual | </ref>. Manual hyperinflation involves the use of a manual resuscitator bag (MRB) connected to oxygen to provide a slow, deep inspiratory breath followed by an inspiratory pause of 1-2 seconds, and a rapid release of the resuscitation bag <ref>Lemes, D. A., Zin, W. A., &amp; Guimarães, F. S. (2009). Hyperinflation using pressure support ventilation | ||
resuscitator bag (MRB) connected to oxygen to provide a slow, deep inspiratory breath followed by an inspiratory pause of 1-2 seconds, and a rapid release of the resuscitation bag <ref>Lemes, D. A., Zin, W. A., &amp; Guimarães, F. S. (2009). Hyperinflation using pressure support ventilation | |||
improves secretion clearance and respiratory mechanics in ventilated patients with pulmonary | improves secretion clearance and respiratory mechanics in ventilated patients with pulmonary | ||
infection: A randomised crossover trial. Australian Journal of Physiotherapy, 55(4), 249–254. | infection: A randomised crossover trial. Australian Journal of Physiotherapy, 55(4), 249–254. | ||
</ref>'''.''' | </ref>'''.''' | ||
=== '''Mechanism of action''' === | === '''Mechanism of action''' === | ||
==== '''To increase volume''' ==== | ==== '''To increase volume''' ==== | ||
Manual hyperinflation is used to manage [[atelectasis]][[Atelectasis.|.]] The mechanism it is thought to work is by increasing alveolar recruitment. The squeezing of the resuscitation bag increases the baseline tidal volumes during inspiration by approximately 1L <ref>Frank, U., Frank, K., &amp; Zimmermann, H. (2015). Effects of respiratory therapy (bagging) on | Manual hyperinflation is used to manage [[atelectasis]][[Atelectasis.|.]] The mechanism it is thought to work is by increasing alveolar recruitment. The squeezing of the resuscitation bag increases the baseline tidal volumes during inspiration by approximately 1L <ref>Frank, U., Frank, K., &amp; Zimmermann, H. (2015). Effects of respiratory therapy (bagging) on | ||
respiratory function, swallowing frequency and vigilance in tracheotomized patients in early | respiratory function, swallowing frequency and vigilance in tracheotomized patients in early | ||
neurorehabilitation. Pneumologie, 69(07), 394-399. | neurorehabilitation. Pneumologie, 69(07), 394-399. | ||
</ref>. This increase in tidal volume plus inspiratory hold allows time for alveoli and collateral airways to open, thereby increasing lung compliance and reducing | </ref>. This increase in tidal volume plus inspiratory hold allows time for alveoli and collateral airways to open, thereby increasing lung compliance and reducing atelectasis <ref name=":1">Bennett, B. G., Thomas, P., &amp; Ntoumenopoulos, G. (2015). Effect of Inspiratory Time and Lung | ||
Compliance on Flow Bias Generated During Manual Hyperinflation: A Bench Study. Respiratory | Compliance on Flow Bias Generated During Manual Hyperinflation: A Bench Study. Respiratory | ||
Care, 60(10), 1449–1458. | Care, 60(10), 1449–1458. | ||
</ref>. | </ref>. | ||
Line 34: | Line 24: | ||
MH not only increases the tidal volume but the quick release of the resuscitation bag increases the elastic recoil of the lung and therefore increases the expiratory flow rate. The expiratory flow rate is necessary to mobilise secretions. | MH not only increases the tidal volume but the quick release of the resuscitation bag increases the elastic recoil of the lung and therefore increases the expiratory flow rate. The expiratory flow rate is necessary to mobilise secretions. | ||
The mechanism for how this works can be explained by the engineering concept of two-phase gas-liquid flow; moving gas in a tube transfers momentum to the stationary liquid, and occurs when the expiratory flow rate is greater than inspiratory flow rate<ref>Maxwell, L., &amp; Ellis, E. (1998). Secretion clearance by manual hyperinflation: Possible mechanisms. | The mechanism for how this works can be explained by the engineering concept of two-phase gas-liquid flow; moving gas in a tube transfers momentum to the stationary liquid, and occurs when the expiratory flow rate is greater than inspiratory flow rate<ref name=":2">Maxwell, L., &amp; Ellis, E. (1998). Secretion clearance by manual hyperinflation: Possible mechanisms. | ||
Physiotherapy Theory and Practice, 14(4), 189–197. | |||
</ref><ref name=":1" /><ref name=":0" />. A normal cough generates very high expiratory airflow, which creates mist flow of the secretions to enable them to be expelled from the airways. However, the expiratory flow generated with Manual Hyperinflation is still much slower than a normal cough, and so moves secretions using annular flow instead. Manual Hyperinflation may therefore prevent mucus plugging and associated lobar collapse <ref name=":3">Paulus,F., Binnekade, J.M., Vroom, M.B. & Schultz MJ (2012) Benefits and risks of manual hyperinflation in intubated and mechanically ventilated intensive care unit a systematic review. Critical Care, 16 (4), R145</ref>. The use of a pressure manometer is recommended to ensure this expiratory flow bias <ref name=":0" />. | |||
Once the secretions have been mobilised, [[suctioning]] is often used to clear them from the patient. | |||
whereby altering the pattern of airflow determines the movement of the liquid (secretions) within the airways (fig 1). A normal cough generates very high expiratory airflow, which creates mist flow of the secretions to enable them to be expelled from the airways. However, the expiratory flow generated with MHI is still much slower than a normal cough, and so moves secretions using annular flow instead. MHI may therefore prevent mucus plugging and associated lobar collapse | |||
=== '''Indications''' <ref name=":4">Hodgson C et al. An investigation of the early effects of manual lung hyperinflation in critically ill patients. Anaesthesia and Intensive Care 2000; 28: 255-261</ref><ref name=":3" /> === | |||
** '''Clearance of retained secretions and mucus plugging''' | |||
** '''Recruitment of areas of [[atelectasis]] or collapse''' | |||
** '''To improve ventilation/perfusion (V/Q) matching''' | |||
** '''To improve lung compliance''' | |||
** '''To improve regional lung ventilation''' | |||
** '''To improve oxygenation''' | |||
=== '''Absolute Contraindications''' === | === '''Absolute Contraindications''' <ref name=":3" /><ref name=":4" /><ref>St George's University Hospital. MANUAL HYPERINFLATION (MHI) (2016) Guidelines for Manual Hyperinflation for Adult Patients, clinical guide https://www.google.com/url?sa=t&rct=j&q=&esrc=s&source=web&cd=&ved=2ahUKEwib9-7oq_frAhWwQxUIHcrpAXUQFjACegQIBRAB&url=http%3A%2F%2Fwww.gicu.sgul.ac.uk%2Fresources-for-current-staff%2Frespiratory-physiotherapy%2FGuidelines%2520MHI%2520v1.2%2520June%25202016.docx%2Fat_download%2Ffile&usg=AOvVaw1AMzDTstWa6GGdBUTSNxsv</ref> === | ||
** '''Undrained [[pneumothorax]]''' | ** '''Undrained [[pneumothorax]]''' | ||
** '''Severe bronchospasm''' | ** '''Severe bronchospasm''' | ||
Line 50: | Line 49: | ||
** '''High Frequency Oscillation Ventilation''' | ** '''High Frequency Oscillation Ventilation''' | ||
=== '''Relative Contraindications''' === | === '''Relative Contraindications'''<ref name=":0" /><ref name=":2" /><ref name=":3" /><ref name=":4" /> === | ||
Note: These relative contraindications are for ‘therapeutic’ | Note: These relative contraindications are for ‘therapeutic’ manual hyperinflation. | ||
{| class="wikitable" | {| class="wikitable" | ||
|'''· Cardiovascular (CVS) instability/arrhythmias''' | |'''· Cardiovascular (CVS) instability/arrhythmias''' | ||
Line 61: | Line 60: | ||
NB! This does not preclude the use of the MRB in resuscitation situations in this patient group | NB! This does not preclude the use of the MRB in resuscitation situations in this patient group | ||
|- | |- | ||
|'''· Severe exacerbation Chronic Obstructive Pulmonary Disease (COPD) / Bronchospasm''' | |'''· Severe exacerbation Chronic Obstructive Pulmonary Disease ([[COPD (Chronic Obstructive Pulmonary Disease)|COPD]]) / Bronchospasm''' | ||
|Increased airway pressure will increase airway irritation and inflammatory response | |Increased airway pressure will increase airway irritation and inflammatory response | ||
|- | |- | ||
Line 94: | Line 93: | ||
|Difficult to co-ordinate the technique | |Difficult to co-ordinate the technique | ||
|- | |- | ||
|'''· Subcutaneous Emphysema''' | |'''· Subcutaneous [[Emphysema]]''' | ||
|May indicate the presence of a pneumothorax | |May indicate the presence of a pneumothorax | ||
|- | |||
|'''· ECMO patients''' | |||
|Should be discussed with on-call ECMO consultant | |||
|} | |} | ||
Line 101: | Line 103: | ||
{{#ev:youtube|209txhJW3iM}} | {{#ev:youtube|209txhJW3iM}} | ||
[[Category:Cardiopulmonary]] | |||
[[Category:Respiratory Disease - Interventions]] | [[Category:Respiratory Disease - Interventions]] | ||
[[Category:Respiratory Disease - Interventions]] | [[Category:Respiratory Disease - Interventions]] | ||
<div class="editorbox"> '''Original Editor '''- [[User:User Name|Sarah Popperwell]] '''Top Contributors''' - {{Special:Contributors/{{FULLPAGENAME}}}}</div> | <div class="editorbox"> '''Original Editor '''- [[User:User Name|Sarah Popperwell]] '''Top Contributors''' - {{Special:Contributors/{{FULLPAGENAME}}}}</div> | ||
<references /> |
Revision as of 11:05, 20 September 2020
Introduction[edit | edit source]
Manual hyperinflation also known as manual ventilation or ‘bagging’, is a technique used by respiratory physiotherapists in the management of ventilated patients or patients self-ventilating through a tracheostomy. Manual hyperinflation is used to increase lung volumes and aid secretion clearance when used in conjunction with suctioning[1]. Manual hyperinflation involves the use of a manual resuscitator bag (MRB) connected to oxygen to provide a slow, deep inspiratory breath followed by an inspiratory pause of 1-2 seconds, and a rapid release of the resuscitation bag [2].
Mechanism of action[edit | edit source]
To increase volume[edit | edit source]
Manual hyperinflation is used to manage atelectasis. The mechanism it is thought to work is by increasing alveolar recruitment. The squeezing of the resuscitation bag increases the baseline tidal volumes during inspiration by approximately 1L [3]. This increase in tidal volume plus inspiratory hold allows time for alveoli and collateral airways to open, thereby increasing lung compliance and reducing atelectasis [4].
For secretion clearance[edit | edit source]
MH not only increases the tidal volume but the quick release of the resuscitation bag increases the elastic recoil of the lung and therefore increases the expiratory flow rate. The expiratory flow rate is necessary to mobilise secretions.
The mechanism for how this works can be explained by the engineering concept of two-phase gas-liquid flow; moving gas in a tube transfers momentum to the stationary liquid, and occurs when the expiratory flow rate is greater than inspiratory flow rate[5][4][1]. A normal cough generates very high expiratory airflow, which creates mist flow of the secretions to enable them to be expelled from the airways. However, the expiratory flow generated with Manual Hyperinflation is still much slower than a normal cough, and so moves secretions using annular flow instead. Manual Hyperinflation may therefore prevent mucus plugging and associated lobar collapse [6]. The use of a pressure manometer is recommended to ensure this expiratory flow bias [1].
Once the secretions have been mobilised, suctioning is often used to clear them from the patient.
whereby altering the pattern of airflow determines the movement of the liquid (secretions) within the airways (fig 1). A normal cough generates very high expiratory airflow, which creates mist flow of the secretions to enable them to be expelled from the airways. However, the expiratory flow generated with MHI is still much slower than a normal cough, and so moves secretions using annular flow instead. MHI may therefore prevent mucus plugging and associated lobar collapse
Indications [7][6][edit | edit source]
- Clearance of retained secretions and mucus plugging
- Recruitment of areas of atelectasis or collapse
- To improve ventilation/perfusion (V/Q) matching
- To improve lung compliance
- To improve regional lung ventilation
- To improve oxygenation
Absolute Contraindications [6][7][8][edit | edit source]
- Undrained pneumothorax
- Severe bronchospasm
- Head injury with ICP > 25mmHg
- Severe arterial hypotension
- High peak end inspiratory pressure (PEEP) ventilation and PEEP dependency
- Nitric Oxide ventilation
- High Frequency Oscillation Ventilation
Relative Contraindications[1][5][6][7][edit | edit source]
Note: These relative contraindications are for ‘therapeutic’ manual hyperinflation.
· Cardiovascular (CVS) instability/arrhythmias | Compromised venous return- further increases effort required to maintain adequate tissue perfusion |
· Acute Respiratory Distress Syndrome (ARDS) | Increases risk of pneumothorax/barotrauma
NB! This does not preclude the use of the MRB in resuscitation situations in this patient group |
· Severe exacerbation Chronic Obstructive Pulmonary Disease (COPD) / Bronchospasm | Increased airway pressure will increase airway irritation and inflammatory response |
· High PEEP (> 10cmH2O) | The break in the circuit will cause loss of PEEP and can de-recruit lung |
· Raised intracranial pressure (ICP) | Increased intrathoracic pressure reduces mean arterial pressure which can compromise cerebral perfusion pressure |
· Proximal Tumor/obstruction | Risk of dislodging or causing trauma |
· Emphysematous Bullae | Increases risk of pneumothorax |
· Recent lung surgery e.g. lobectomy/pneumonectomy | High airway pressure may cause trauma/pneumothorax. Check with surgeons regarding stump pressure. |
· Hypotension (Systolic <80) | Increased positive pressure in thoracic cavity compromises venous return – reduces cardiac output |
· Patients dependent on hypoxic drive | High levels of O2 being delivered/increased PaO2 levels may reduce drive to breathe |
· Acute Head Injury | As for raised ICP |
· Unexplained Haemoptysis | May be indicative of acute trauma to the lung parenchyma |
· High respiratory rate | Difficult to co-ordinate the technique |
· Subcutaneous Emphysema | May indicate the presence of a pneumothorax |
· ECMO patients | Should be discussed with on-call ECMO consultant |
Technique[edit | edit source]
- ↑ 1.0 1.1 1.2 1.3 Volpe, M. S., Naves, J. M., Ribeiro, G. G., Ruas, G., & Tucci, M. R. (2018). Effects of manual hyperinflation, clinical practice versus expert recommendation, on displacement of mucus simulant: A laboratory study. PLoS ONE, 13(2), 1–11.
- ↑ Lemes, D. A., Zin, W. A., & Guimarães, F. S. (2009). Hyperinflation using pressure support ventilation improves secretion clearance and respiratory mechanics in ventilated patients with pulmonary infection: A randomised crossover trial. Australian Journal of Physiotherapy, 55(4), 249–254.
- ↑ Frank, U., Frank, K., & Zimmermann, H. (2015). Effects of respiratory therapy (bagging) on respiratory function, swallowing frequency and vigilance in tracheotomized patients in early neurorehabilitation. Pneumologie, 69(07), 394-399.
- ↑ 4.0 4.1 Bennett, B. G., Thomas, P., & Ntoumenopoulos, G. (2015). Effect of Inspiratory Time and Lung Compliance on Flow Bias Generated During Manual Hyperinflation: A Bench Study. Respiratory Care, 60(10), 1449–1458.
- ↑ 5.0 5.1 Maxwell, L., & Ellis, E. (1998). Secretion clearance by manual hyperinflation: Possible mechanisms. Physiotherapy Theory and Practice, 14(4), 189–197.
- ↑ 6.0 6.1 6.2 6.3 Paulus,F., Binnekade, J.M., Vroom, M.B. & Schultz MJ (2012) Benefits and risks of manual hyperinflation in intubated and mechanically ventilated intensive care unit a systematic review. Critical Care, 16 (4), R145
- ↑ 7.0 7.1 7.2 Hodgson C et al. An investigation of the early effects of manual lung hyperinflation in critically ill patients. Anaesthesia and Intensive Care 2000; 28: 255-261
- ↑ St George's University Hospital. MANUAL HYPERINFLATION (MHI) (2016) Guidelines for Manual Hyperinflation for Adult Patients, clinical guide https://www.google.com/url?sa=t&rct=j&q=&esrc=s&source=web&cd=&ved=2ahUKEwib9-7oq_frAhWwQxUIHcrpAXUQFjACegQIBRAB&url=http%3A%2F%2Fwww.gicu.sgul.ac.uk%2Fresources-for-current-staff%2Frespiratory-physiotherapy%2FGuidelines%2520MHI%2520v1.2%2520June%25202016.docx%2Fat_download%2Ffile&usg=AOvVaw1AMzDTstWa6GGdBUTSNxsv