Functional Index of Hand Osteoarthritis (FIHOA): Difference between revisions

m (Grammar corrections)
m (linked to existing PP pages, grammar corrections)
 
Line 5: Line 5:
</div>  
</div>  
== Objective  ==
== Objective  ==
The FIHOA is a measure to assess [[Hand Function|hand function]] in p[[Hand Function|ople]]<nowiki/>s with [[Wrist and Hand Osteoarthritis|hand osteoarthritis]] (OA). It is a 10 item questionnaire developed by Dreiser et a[[Wrist and Hand Osteoarthritis|.]]<nowiki/>l in 1995<ref name=":0">Dreiser R, Maheu E, Guillou GB, Caspard H, Grouin JM. Validation of an algofunctional index for osteoarthritis of the hand. Rev Rhum Engl Ed. 1995; 62: 43S– 53S.</ref><ref>Dreiser RL, Maheu E, Guillou GB. Sensitivity to change of the functional index for hand osteoarthritis. Osteoarthritis Cartilage 2000; 8: S25– 8.</ref>. It has been translated iton French, Dutc,h and Argentinian versions. It is targetedats the functional capacity of hands in OA- affected patients<ref name=":0" />. It is also called as Dreiser's index.<br>
The FIHOA is a measure to assess [[Hand Function|hand function]] in people with [[Wrist and Hand Osteoarthritis|hand osteoarthritis]] (OA). It is a 10-item questionnaire developed by Dreiser et a[[Wrist and Hand Osteoarthritis|.]]<nowiki/>l in 1995<ref name=":0">Dreiser R, Maheu E, Guillou GB, Caspard H, Grouin JM. Validation of an algofunctional index for osteoarthritis of the hand. Rev Rhum Engl Ed. 1995; 62: 43S– 53S.</ref><ref>Dreiser RL, Maheu E, Guillou GB. Sensitivity to change of the functional index for hand osteoarthritis. Osteoarthritis Cartilage 2000; 8: S25– 8.</ref>. It has been translated into French, Dutch, and Argentinian versions. It is targeted at the functional capacity of hands in [[Osteoarthritis|OA]]-affected patients<ref name=":0" />. It is also called Dreiser's index.<br>


== Intended Population  ==
== Intended Population  ==
The targeted population is [[Osteoarthritis]] patients but it can also be used in [[Rheumatoid Arthritis|Rheumatoid arthritis]], in patients whose hand functions need to be assessed.<br>
The targeted population is [[Osteoarthritis]] patients, but it can also be used in [[Rheumatoid Arthritis|Rheumatoid arthritis]], in patients whose [[Hand Function|hand function]] needs to be assessed.<br>


== Method of Use  ==
== Method of Use  ==
'''''Equipment Required:'''''  
'''''Equipment Required:'''''  


None. Questionnaire based.
None. Questionnaire-based.


'''''Time to administer:'''''
'''''Time to administer:'''''
Line 25: Line 25:
'''''Method of Administration:'''''  
'''''Method of Administration:'''''  


Physician/ physiotherapist administered, self - reported.
Physician/physiotherapist administered, self-reported


== Instrument ==
== Instrument ==
It contains 10 question with a score range of 0-30<ref name=":0" />.
It contains 10 questions with a score range of 0–30<ref name=":0" />.
{| class="wikitable"
{| class="wikitable"
!Sr. no.
!Sr. no.
Line 113: Line 113:
0=possible without difficulty, 1=possible with slight difficulty, 2=possible with important difficulty, 3=impossible.
0=possible without difficulty, 1=possible with slight difficulty, 2=possible with important difficulty, 3=impossible.


Total scores indicate hand function. Lower the scores, better the hand function<ref name=":0" />.   
Total scores indicate [[Hand Function|hand function]]. Lower the scores, better the hand function<ref name=":0" />.   


== Psychometric Properties  ==
== Psychometric Properties  ==
'''Reliability:'''  
'''Reliability:'''  
# Interrater: in OA, Cronbach's alpha : 0.90<ref name=":1">Poole JL, Lucero SL, Mynatt R. Self‐reports and performance based tests of hand function in persons with osteoarthritis. Phys Occup Ther Geriatr 2010; 28: 249– 58.</ref><ref name=":2">Moe R, Garratt A, Slatkowsky‐Christensen B, Maheu E, Mowinckel P, Kvien T, et al. Concurrent evaluation of data quality, reliability and validity of the Australian/Canadian Osteoarthritis Hand Index and the Functional Index for Hand Osteoarthritis. Rheumatology (Oxford). 2010; 49: 2327– 36.</ref>. In RA, Cronbach’s alpha test :0.94<ref name=":3">Bande JM, Caracciolo JÁ, Papasidero SB, Santa Cruz MJ, Medina MA, Klajn DS, Battaglia MG, Giantinoto J, Pelagagge F. Validation of the Functional Index for Hand Osteoarthritis (FIHOA) in Patients with Rheumatoid Arthritis [abstract]. ''Arthritis'' Rheumatol''.'' 2018; 70 (suppl 10). Accessed October 24, 2020.
# Interrater: in [[Osteoarthritis|OA]], Cronbach's alpha is 0.90<ref name=":1">Poole JL, Lucero SL, Mynatt R. Self‐reports and performance based tests of hand function in persons with osteoarthritis. Phys Occup Ther Geriatr 2010; 28: 249– 58.</ref><ref name=":2">Moe R, Garratt A, Slatkowsky‐Christensen B, Maheu E, Mowinckel P, Kvien T, et al. Concurrent evaluation of data quality, reliability and validity of the Australian/Canadian Osteoarthritis Hand Index and the Functional Index for Hand Osteoarthritis. Rheumatology (Oxford). 2010; 49: 2327– 36.</ref>. In RA, Cronbach’s alpha test: 0.94<ref name=":3">Bande JM, Caracciolo JÁ, Papasidero SB, Santa Cruz MJ, Medina MA, Klajn DS, Battaglia MG, Giantinoto J, Pelagagge F. Validation of the Functional Index for Hand Osteoarthritis (FIHOA) in Patients with Rheumatoid Arthritis [abstract]. ''Arthritis'' Rheumatol''.'' 2018; 70 (suppl 10). Accessed October 24, 2020.


https://acrabstracts.org/abstract/validation-of-the-functional-index-for-hand-osteoarthritis-fihoa-in-patients-with-rheumatoid-arthritis/  
https://acrabstracts.org/abstract/validation-of-the-functional-index-for-hand-osteoarthritis-fihoa-in-patients-with-rheumatoid-arthritis/  
</ref>  
</ref>  
# Test- Retest: by administering the FIHOA 2 times 1 week apart gave an ICC of 0.74 and 2 times with a 5‐day interval yielded an ICC of 0.96 in OA<ref name=":1" /><ref name=":2" />
# Test-Retest: by administering the FIHOA two times 1 week apart gave an ICC of 0.74 and two times with a 5-day interval yielded an ICC of 0.96 in [[Osteoarthritis|OA]]<ref name=":1" /><ref name=":2" />
# Intra-rater: by testing patients with OA 2 times 1 hour apart. Correlations between the scores were 0.95<ref name=":1" /><ref name=":2" />
# Intra-rater: by testing patients with [[Osteoarthritis|OA]] two times, 1 hour apart. The correlations between the scores were 0.95<ref name=":1" /><ref name=":2" />
'''Validity:'''
'''Validity:'''


For OA, FIHOA correlated with<ref name=":2" />  
For [[Osteoarthritis|OA]], FIHOA correlated with<ref name=":2" />  
# the Cochin Hand Function Scale (rs = 0.89) and  
# the Cochin Hand Function Scale (rs = 0.89) and  
# Michigan Hand Outcomes Questionnaire (rs = 0.86),  
# Michigan Hand Outcomes Questionnaire (rs = 0.86),  
# total Australian Canadian Osteoarthritis Hand Index (rs = 0.76)
# total Australian Canadian Osteoarthritis Hand Index (rs = 0.76)
Thus, it was found reliable, valid for OA.
Thus, it was found reliable and valid for [[Osteoarthritis|OA]].


For RA, FIHOA was found to be reliable, valid and reproducible<ref name=":3" />.
For [[Rheumatoid Arthritis|RA]], FIHOA was found to be reliable, valid, and reproducible<ref name=":3" />.


<span style="font-size: 20px; font-weight: normal;" class="Apple-style-span"></span><br>   
<span style="font-size: 20px; font-weight: normal;" class="Apple-style-span"></span><br>   

Latest revision as of 10:48, 30 September 2023

Original Editor - Rucha Gadgil

Top Contributors - Rucha Gadgil, Temitope Olowoyeye, Kim Jackson and Shaimaa Eldib  

Objective[edit | edit source]

The FIHOA is a measure to assess hand function in people with hand osteoarthritis (OA). It is a 10-item questionnaire developed by Dreiser et a.l in 1995[1][2]. It has been translated into French, Dutch, and Argentinian versions. It is targeted at the functional capacity of hands in OA-affected patients[1]. It is also called Dreiser's index.

Intended Population[edit | edit source]

The targeted population is Osteoarthritis patients, but it can also be used in Rheumatoid arthritis, in patients whose hand function needs to be assessed.

Method of Use[edit | edit source]

Equipment Required:

None. Questionnaire-based.

Time to administer:

5-10 mins.

Training Required:

None.

Method of Administration:

Physician/physiotherapist administered, self-reported

Instrument[edit | edit source]

It contains 10 questions with a score range of 0–30[1].

Sr. no. Question asked Scoring
0 1 2 3
1 Are you able to turn a key in a lock?
2 Are you able to cut meat with a knife?
3 Are you able to cut cloth or paper with a pair of scissors?
4 Are you able to lift a full bottle with the hand?
5 Are you able to clench your fist?
6 Are you able to tie a knot?
7 For women: Are you able to sew? For men: Are you able to use a screwdriver?
8 Are you able to fasten buttons? 9. 10.
9 Are you able to write for a long period of time?
10 Would you accept a handshake without reluctance?

0=possible without difficulty, 1=possible with slight difficulty, 2=possible with important difficulty, 3=impossible.

Total scores indicate hand function. Lower the scores, better the hand function[1].

Psychometric Properties[edit | edit source]

Reliability:

  1. Interrater: in OA, Cronbach's alpha is 0.90[3][4]. In RA, Cronbach’s alpha test: 0.94[5]
  2. Test-Retest: by administering the FIHOA two times 1 week apart gave an ICC of 0.74 and two times with a 5-day interval yielded an ICC of 0.96 in OA[3][4]
  3. Intra-rater: by testing patients with OA two times, 1 hour apart. The correlations between the scores were 0.95[3][4]

Validity:

For OA, FIHOA correlated with[4]

  1. the Cochin Hand Function Scale (rs = 0.89) and
  2. Michigan Hand Outcomes Questionnaire (rs = 0.86),
  3. total Australian Canadian Osteoarthritis Hand Index (rs = 0.76)

Thus, it was found reliable and valid for OA.

For RA, FIHOA was found to be reliable, valid, and reproducible[5].


References[edit | edit source]

  1. 1.0 1.1 1.2 1.3 Dreiser R, Maheu E, Guillou GB, Caspard H, Grouin JM. Validation of an algofunctional index for osteoarthritis of the hand. Rev Rhum Engl Ed. 1995; 62: 43S– 53S.
  2. Dreiser RL, Maheu E, Guillou GB. Sensitivity to change of the functional index for hand osteoarthritis. Osteoarthritis Cartilage 2000; 8: S25– 8.
  3. 3.0 3.1 3.2 Poole JL, Lucero SL, Mynatt R. Self‐reports and performance based tests of hand function in persons with osteoarthritis. Phys Occup Ther Geriatr 2010; 28: 249– 58.
  4. 4.0 4.1 4.2 4.3 Moe R, Garratt A, Slatkowsky‐Christensen B, Maheu E, Mowinckel P, Kvien T, et al. Concurrent evaluation of data quality, reliability and validity of the Australian/Canadian Osteoarthritis Hand Index and the Functional Index for Hand Osteoarthritis. Rheumatology (Oxford). 2010; 49: 2327– 36.
  5. 5.0 5.1 Bande JM, Caracciolo JÁ, Papasidero SB, Santa Cruz MJ, Medina MA, Klajn DS, Battaglia MG, Giantinoto J, Pelagagge F. Validation of the Functional Index for Hand Osteoarthritis (FIHOA) in Patients with Rheumatoid Arthritis [abstract]. Arthritis Rheumatol. 2018; 70 (suppl 10). Accessed October 24, 2020. https://acrabstracts.org/abstract/validation-of-the-functional-index-for-hand-osteoarthritis-fihoa-in-patients-with-rheumatoid-arthritis/