Dual Energy X-ray Absorptiometry (DEXA Scan): Difference between revisions

No edit summary
No edit summary
Line 33: Line 33:
* Scores between negative 1 and negative 2.5 reflect a diagnosis of osteopenia.
* Scores between negative 1 and negative 2.5 reflect a diagnosis of osteopenia.
* Scores below negative 2.5 reflect a diagnosis of osteoporosis.
* Scores below negative 2.5 reflect a diagnosis of osteoporosis.
== 2 types of DEXA scans ==
== 2 Types of DEXA scans ==
* '''Central DEXA'''
* '''Central DEXA'''
** The [https://www.nof.org/patients/diagnosis-information/bone-density-examtesting/ National Osteoporosis Foundation] recommends a central DEXA test of the radius bone in the forearm when testing can’t be done on the hip and spine
** The [https://www.nof.org/patients/diagnosis-information/bone-density-examtesting/ National Osteoporosis Foundation] recommends a central DEXA test of the radius bone in the forearm when testing can’t be done on the hip and spine
Line 48: Line 48:


== Reliability and Validity  ==
== Reliability and Validity  ==
We examined data for density changes by bone compression after TAA, and found “good” results for internal reliability but only “acceptable” results for external reliability<ref name=":0">Venjakob E, Yao D, Ettinger S, Claassen L, Schwarze M, Plaass C, Stukenborg-Colsman C, Lerch M. Feasibility and Reliability of DEXA Analysis after Total Ankle Arthroplasty: A Cadaver Study. Foot and Ankle Surgery. 2020 Mar 6.</ref>.
Repeatability of total body DEXA measurements was excellent for bone mineral content (''r'' = 0.99), LM (''r'' = 0.99), fat tissue mass (''r'' = 1.00), and bone mineral density (''r'' = 0.98) in supine scanning <ref name=":1" /> Results were also "good" for internal reliability but only “acceptable” for external reliability<ref name=":0">Venjakob E, Yao D, Ettinger S, Claassen L, Schwarze M, Plaass C, Stukenborg-Colsman C, Lerch M. Feasibility and Reliability of DEXA Analysis after Total Ankle Arthroplasty: A Cadaver Study. Foot and Ankle Surgery. 2020 Mar 6.</ref>.


Repeatability of total body DEXA measurements was excellent for bone mineral content (''r'' = 0.99), LM (''r'' = 0.99), fat tissue mass (''r'' = 1.00), and bone mineral density (''r'' = 0.98) in supine scanning. Change of position from supine to prone slightly decreased the reproducibility of total body measurements. Reproducibility of regional measurements was inferior to total body results; especially in the upper extremity, the repeated automatic LM measurements in supine-supine positions produced ''r'' values as low as 0.74 but increased to 0.93 after manual adjustment of the ROIs. To obtain maximal reliability of the composition measurements, we recommend manual checking of machine-made ROIs and, if needed, manual adjustment to avoid measurement errors.<ref>Lohman M, Tallroth K, Kettunen JA, Marttinen MT. Reproducibility of dual-energy x-ray absorptiometry total and regional body composition measurements using different scanning positions and definitions of regions. Metabolism. 2009 Nov 1;58(11):1663-8.</ref>
Change of position from supine to prone slightly decreased the reproducibility of total body measurements.<ref name=":1">Lohman M, Tallroth K, Kettunen JA, Marttinen MT. Reproducibility of dual-energy x-ray absorptiometry total and regional body composition measurements using different scanning positions and definitions of regions. Metabolism. 2009 Nov 1;58(11):1663-8.</ref>


== Limitations ==
== Limitations ==
Most Central DEXA machines cannot measure the hip and spine of a patient that weighs more than 300 pounds or 136kg. In this case, a central DEXA of the radius and the calcaneous can be carries out.
Most Central DEXA machines cannot measure the hip and spine of a patient that weighs more than 300 pounds or 136kg. In this case, a central DEXA of the radius and the calcaneous can be carries out.<span style="font-size: 20px; font-weight: normal;" class="Apple-style-span"></span>
 
== Conclusions ==
The results were reliable and reproducible.<ref name=":0" /><span style="font-size: 20px; font-weight: normal;" class="Apple-style-span"></span>
== Links  ==
== Links  ==



Revision as of 10:25, 26 January 2021

Original Editor - User Name

Top Contributors - Carin Hunter, Lucinda hampton, Tarina van der Stockt and Kim Jackson  

Objective[edit | edit source]

Dual Energy X-ray Absorptiometry[1] (or DEXA, or bone densitometry) is used primarily for osteoporosis [2]tests. 2 narrow x-ray beams are emitted at a 90 degree angles across the patient. The most commonly imaged areas are he hip (head of the femur), lower back (lumbar spine) or heel (calcaneum), One peak is absorbed by soft tissue and the other by bone. When the soft tissue absorption amount is subtracted from the total absorption, the remainder is the bone mineral density.

Although not common, it can be used to measure total body fat. The test is noninvasive, fast, and more accurate than a regular X-ray. It involves an extremely low level of radiation.

Intended Population[edit | edit source]

The World Health Organization (WHO) established dual x-ray absorptiometry tests scans (DEXA) of the central skeleton is the best test for assessing bone mineral density

[3]

National Osteoporosis Foundation recommends that you have a DEXA scan if:

  • you are a woman age 65 or older
  • you are a man age 70 or older
  • you break a bone after age 50
  • you are a woman of menopausal age with risk factors
  • you are a postmenopausal woman under age 65 with risk factors
  • you are a man age 50-69 with risk factors

A bone density test may also be necessary if you have any of the following:

  • an X-ray of your spine showing a break or bone loss in your spine
  • back pain with a possible break in your spine
  • height loss of ½ inch or more within one year
  • total height loss of 1½ inches from your original height

Interpretation of scores[edit | edit source]

Bone density test results are reported using T-scores. T-scores are in reference to that of a healthy 30 year old adult

  • A t-score reflects the difference between the measured bone mineral density and the mean value of bone mineral density in young adults.
  • The WHO has defined normal bone mineral density for women as a t-score within one standard deviation of the young adult mean.
  • Scores between negative 1 and negative 2.5 reflect a diagnosis of osteopenia.
  • Scores below negative 2.5 reflect a diagnosis of osteoporosis.

2 Types of DEXA scans[edit | edit source]

  • Central DEXA
    • The National Osteoporosis Foundation recommends a central DEXA test of the radius bone in the forearm when testing can’t be done on the hip and spine
    • This scan will assist a diagnosis of osteoporosis which is a risk factor for fractures as well as predicting future breaks in other bones.
    • For this scan you remain fully clothed as long as there are no buttons or zippers in the way of the area to be scanned.
    • The scan takes less than 15 minutes and is painless.
    • For the most accurate comparison between scans, have the test done at the same location with the same equipment if possible.
  • Screening Tests or peripheral tests
    • pDXA (peripheral dual energy x-ray absorptiometry)
    • QUS (quantitative ultrasound)
    • pQCT (peripheral quantitative computed tomography)

The screening tests measure bone density in the lower arm, wrist, finger or heel. A screening test cannot diagnose osteoporosis but the can identify an individual who would benefit from additional investigations.

Reliability and Validity[edit | edit source]

Repeatability of total body DEXA measurements was excellent for bone mineral content (r = 0.99), LM (r = 0.99), fat tissue mass (r = 1.00), and bone mineral density (r = 0.98) in supine scanning [4] Results were also "good" for internal reliability but only “acceptable” for external reliability[5].

Change of position from supine to prone slightly decreased the reproducibility of total body measurements.[4]

Limitations[edit | edit source]

Most Central DEXA machines cannot measure the hip and spine of a patient that weighs more than 300 pounds or 136kg. In this case, a central DEXA of the radius and the calcaneous can be carries out.

Links[edit | edit source]

References[edit | edit source]

  1. https://physio-pedia.com/Medical_Imaging?utm_source=physiopedia&utm_medium=search&utm_campaign=ongoing_internal
  2. https://physio-pedia.com/Osteoporosis
  3. https://www.nof.org/patients/diagnosis-information/bone-density-examtesting/
  4. 4.0 4.1 Lohman M, Tallroth K, Kettunen JA, Marttinen MT. Reproducibility of dual-energy x-ray absorptiometry total and regional body composition measurements using different scanning positions and definitions of regions. Metabolism. 2009 Nov 1;58(11):1663-8.
  5. Venjakob E, Yao D, Ettinger S, Claassen L, Schwarze M, Plaass C, Stukenborg-Colsman C, Lerch M. Feasibility and Reliability of DEXA Analysis after Total Ankle Arthroplasty: A Cadaver Study. Foot and Ankle Surgery. 2020 Mar 6.