Tardieu Scale: Difference between revisions

No edit summary
No edit summary
Line 9: Line 9:


The Tardieu Scale and the Modified Tardieu Scale are used clinically to measure spasticity in patients with neurological conditions.
The Tardieu Scale and the Modified Tardieu Scale are used clinically to measure spasticity in patients with neurological conditions.
The Tardieu Scale was developed by Tardieu ''et al'' in 1954. Held and Pierrot-Deseilligny modified it in 1969, and it was further modified in 1999 by Boyd and Graham<ref>Abolhasani H, Ansari NN, Naghdi S, Mansouri K, Ghotbi N, Hasson S. Comparing the validity of the Modified Modified Ashworth Scale (MMAS) and the Modified Tardieu Scale (MTS) in the assessment of wrist flexor spasticity in patients with stroke: protocol for a neurophysiological study. BMJ open. 2012 Jan 1;2(6).</ref>
== Purpose  ==
== Purpose  ==
The purpose of these scales is to quantify spasticity by assessing the muscle's response to different stretch velocities and by determining the spasticity angle .
The purpose of these scales is to quantify spasticity by assessing the muscle's response to different stretch velocities and by determining the spasticity angle .
Line 16: Line 18:
== Technique  ==
== Technique  ==


Describe how to carry out this assessment technique here
A standard goniometer will be utilised to measure R2 and R1. The patient will be in testing position according to the muscle to be tested. The stretching velocity of V1 and V3 will be applied to measure R2 and R1, respectively. The quality of muscle reaction will be graded at the stretching velocity of V3 as well.16 ,17 The difference between R2 and R1 will be the measure of the dynamic component of spasticity.


== Scoring ==
== Scoring ==

Revision as of 12:15, 13 April 2021

This article or area is currently under construction and may only be partially complete. Please come back soon to see the finished work! (13/04/2021)

Original Editor - User Name
Top Contributors - Shreya Pavaskar, Kim Jackson and Rucha Gadgil

Introduction[edit | edit source]

The Tardieu Scale and the Modified Tardieu Scale are used clinically to measure spasticity in patients with neurological conditions.

The Tardieu Scale was developed by Tardieu et al in 1954. Held and Pierrot-Deseilligny modified it in 1969, and it was further modified in 1999 by Boyd and Graham[1]

Purpose[edit | edit source]

The purpose of these scales is to quantify spasticity by assessing the muscle's response to different stretch velocities and by determining the spasticity angle .

Tardieu scale has been utilized in the following populations: stroke, spinal cord injury, multiple sclerosis, cerebral palsy, traumatic brain injury, pediatric hypertonia and central nervous system lesions

Technique[edit | edit source]

A standard goniometer will be utilised to measure R2 and R1. The patient will be in testing position according to the muscle to be tested. The stretching velocity of V1 and V3 will be applied to measure R2 and R1, respectively. The quality of muscle reaction will be graded at the stretching velocity of V3 as well.16 ,17 The difference between R2 and R1 will be the measure of the dynamic component of spasticity.

Scoring[edit | edit source]

The scoring is done as follows[2] -

Quality of Muscle Reaction

0 No resistance throughout passive movement
1 Slight resistance throughout,with no clear catch at a precise angle
2 Clear catch at a precise angle followed by release
3 Fatiguable Clonus (< 10 secs) occurring at a precise angleFatiguable Clonus (< 10 secs) occurring at a precise angle
4 Unfatiguable Clonus (> 10 secs) occurring at a precise angle
5 Joint immobile

Velocity to Stretch

V1 As slow as possible
V2 Speed of the limb segment falling (with gravitational pull)
V3 At a fast rate (>gravitational pull)

Spasticity Angle

R1 Angle of catch seen at Velocity V2 or V3
R2 Full range of motion achieved when muscle is at rest and tested at V1 velocity

Evidence[edit | edit source]

Provide the evidence for this technique here

Resources[edit | edit source]

add any relevant resources here

References[edit | edit source]

  1. Abolhasani H, Ansari NN, Naghdi S, Mansouri K, Ghotbi N, Hasson S. Comparing the validity of the Modified Modified Ashworth Scale (MMAS) and the Modified Tardieu Scale (MTS) in the assessment of wrist flexor spasticity in patients with stroke: protocol for a neurophysiological study. BMJ open. 2012 Jan 1;2(6).
  2. Morris S. Ashworth and Tardieu Scales: Their clinical relevance for measuring spasticity in adult and paediatric neurological populations. Physical Therapy Reviews. 2002 Mar 1;7(1):53-62.