Goniometry: Wrist Ulnar Deviation: Difference between revisions

(Created page with "== Anatomical Movement == Wrist ulnar deviation == Testing position == Patient is seated with elbow flexed to 90 degrees and wrist over the edge of a table or plinth with for...")
(No difference)

Revision as of 12:20, 1 February 2019

Anatomical Movement[edit | edit source]

Wrist ulnar deviation

Testing position[edit | edit source]

Patient is seated with elbow flexed to 90 degrees and wrist over the edge of a table or plinth with forearm in pronation

Goniometer Placement[edit | edit source]

AXIS LOCATION STATIONARY ARM MOVEMENT ARM
capitate dorsal midline of forearm parallel with longitudinal axis of 3rd metacarpal

Expected Findings[edit | edit source]

Expected range of motion is 20 degrees

References[edit | edit source]