Modified Clinical Test for Sensory Interaction on Balance: Difference between revisions
Memoona Awan (talk | contribs) mNo edit summary |
Memoona Awan (talk | contribs) (added : under construction banner, Template , content , table and reference.) |
||
Line 1: | Line 1: | ||
<div class="editorbox"> <div class="noeditbox">This article or area is currently under construction and may only be partially complete. Please come back soon to see the finished work! ({{REVISIONDAY}}/{{REVISIONMONTH}}/{{REVISIONYEAR}})</div> '''Original Editor '''- [[User:Memoona Awan|User Name]]<br> | <div class="editorbox"> <div class="noeditbox">This article or area is currently under construction and may only be partially complete. Please come back soon to see the finished work! ({{REVISIONDAY}}/{{REVISIONMONTH}}/{{REVISIONYEAR}})</div> '''Original Editor '''- [[User:Memoona Awan|User Name]]<br> | ||
'''Top Contributors''' - {{Special:Contributors/{{FULLPAGENAME}}}}</div> | '''Top Contributors''' - {{Special:Contributors/{{FULLPAGENAME}}}}</div> | ||
== Purpose | == Purpose == | ||
It is used for balance analysis and to determine dependence of individual on all sensory systems ( vision, vestibular and somatosensory ) which maintain balance.<ref>[https://www.worldscientific.com/doi/epdf/10.1142/S1013702520500134 The e®ect of the type of foam pad used in the modi ̄edClinical Test of Sensory Interaction and Balance (mCTSIB)on the accuracy in identifying older adults with fall history.] Hong Kong Physiotherapy Journal. 2020;40(2):133–143.</ref>minimal cost , | |||
== Technique | == Technique == | ||
{| class="wikitable" | |||
|+M-CTSIB | |||
! colspan="3" |On Floor | |||
! colspan="3" |Complain surface ( Foam ) | |||
|- | |||
!Condition 1 | |||
!Condition 2 | |||
!Condition 3 | |||
!Condition 4 | |||
!Condition 5 | |||
!Condition 6 | |||
|- | |||
|On floor | |||
Arms across chest | |||
feet together | |||
|On floor | |||
Arms across chest | |||
feet together | |||
|On floor | |||
Arms across chest | |||
feet together | |||
|On floor | |||
Arms across chest | |||
feet together | |||
|On floor | |||
Arms across chest | |||
feet together | |||
|On floor | |||
Arms across chest | |||
feet together | |||
|- | |||
|hold 30 sec | |||
|hold 30 sec | |||
|hold 30 sec | |||
|hold 30 sec | |||
|hold 30 sec | |||
|hold 30 sec | |||
|- | |||
|Eyes open | |||
|Eyes closed | |||
|Visual dome | |||
|Eyes open | |||
|Eyes closed | |||
|Visual dome | |||
|} | |||
== Evidence == | |||
reliability | |||
validity | |||
== Resources == | == Resources == |
Revision as of 20:03, 24 November 2023
Top Contributors - Memoona Awan
Purpose[edit | edit source]
It is used for balance analysis and to determine dependence of individual on all sensory systems ( vision, vestibular and somatosensory ) which maintain balance.[1]minimal cost ,
Technique[edit | edit source]
On Floor | Complain surface ( Foam ) | ||||
---|---|---|---|---|---|
Condition 1 | Condition 2 | Condition 3 | Condition 4 | Condition 5 | Condition 6 |
On floor
Arms across chest feet together |
On floor
Arms across chest feet together |
On floor
Arms across chest feet together |
On floor
Arms across chest feet together |
On floor
Arms across chest feet together |
On floor
Arms across chest feet together |
hold 30 sec | hold 30 sec | hold 30 sec | hold 30 sec | hold 30 sec | hold 30 sec |
Eyes open | Eyes closed | Visual dome | Eyes open | Eyes closed | Visual dome |
Evidence[edit | edit source]
reliability
validity
Resources[edit | edit source]
add any relevant resources here
References[edit | edit source]
- ↑ The e®ect of the type of foam pad used in the modi ̄edClinical Test of Sensory Interaction and Balance (mCTSIB)on the accuracy in identifying older adults with fall history. Hong Kong Physiotherapy Journal. 2020;40(2):133–143.