[1]Anatomical Movement[edit | edit source]
Wrist flexion
Testing position[edit | edit source]
Patient is seated with the shoulder abducted to 90 degrees, elbow flexed to 90 degrees and wrist over the edge of a table or plinth with forearm in pronation.
Goniometer Placement[edit | edit source]
AXIS LOCATION | STATIONARY ARM | MOVEMENT ARM |
---|---|---|
over lateral triquetrial bone | parallel with the ulnar | parallel with longitudinal axis of 5th metacarpal |
Expected Findings[edit | edit source]
Expected range of motion is 0- 75 degrees