Goniometry: Hip Abduction: Difference between revisions
Claire Knott (talk | contribs) No edit summary |
No edit summary |
||
Line 3: | Line 3: | ||
== Testing position == | == Testing position == | ||
Patient is supine with hips and knees in neutral | Patient is supine with hips and knees in neutral | ||
== Goniometer Placement == | == Goniometer Placement == | ||
Line 15: | Line 15: | ||
|parallel to femur, directed to centre of patella | |parallel to femur, directed to centre of patella | ||
|} | |} | ||
{{#ev:youtube|CjotehYttpE}} | |||
== Expected Findings == | == Expected Findings == | ||
Expected range of motion is | Expected range of motion is 0- 40 degrees (measured from starting position) | ||
== References == | == References == |
Revision as of 09:55, 12 February 2019
Anatomical Movement[edit | edit source]
Hip abduction
Testing position[edit | edit source]
Patient is supine with hips and knees in neutral
Goniometer Placement[edit | edit source]
AXIS LOCATION | STATIONARY ARM | MOVEMENT ARM |
---|---|---|
ASIS on measured side | directed to opposite ASIS | parallel to femur, directed to centre of patella |
Expected Findings[edit | edit source]
Expected range of motion is 0- 40 degrees (measured from starting position)