Timed Up and Go Test (TUG): Difference between revisions

(Created page with "Timed Up and Go Test (TUG) Objective: to determine fall risk and measure progress of balance, sit to stand, and walking. Intended Population: This test was initially desig...")
 
No edit summary
Line 1: Line 1:
Timed Up and Go Test (TUG)
Timed Up and Go Test (TUG)  


Objective: to determine fall risk and measure progress of balance, sit to stand, and walking.
'''Objective'''


Intended Population: This test was initially designed for elderly persons, but is used for people with Parkinsons, Multiple Sclerosis, hip fracture, Alzheimer, CVA, and others.  
To determine fall risk and measure progress of balance, sit to stand, and walking.  


Method of Use: The patient starts in a seated position, stands up upon therapist’s command, walks 3 meters, turns around, walks back to the chair and sits down. The time stops when the patient is seated. The subject is allowed to use an assistive device, and a practice trial should be completed before the timed trial. Be sure to document the assistive device used.
'''Intended Population'''
This test was initially designed for elderly persons, but is used for people with Parkinsons, Multiple Sclerosis, hip fracture, Alzheimer, CVA, and others.
 
'''Method of Use'''
The patient starts in a seated position, stands up upon therapist’s command, walks 3 meters, turns around, walks back to the chair and sits down. The time stops when the patient is seated. The subject is allowed to use an assistive device, and a practice trial should be completed before the timed trial. Be sure to document the assistive device used.
 
      ''Cut-off time for high risk of falls'': Cut-off times to classify subjects as high risk for falling vary based on the study and
 
&nbsp;&nbsp;&nbsp;&nbsp; &nbsp;participants. By using regression analysis Shumway-Cook used&nbsp;14 seconds as the cut-off. Thus, if a subject took 14 <span id="fck_dom_range_temp_1320012034171_666" /><span id="fck_dom_range_temp_1320012034171_254" /><span id="fck_dom_range_temp_1320012034296_94" /><span id="fck_dom_range_temp_1320012034312_115" /><br>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; seconds or longer he or she was classified as high-risk for falling.<sup>1</sup><br>
 
&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; ''Materials Needed'': one chair with armrest, stopwatch, tape (to mark 3 meters).
 
'''Evidence'''
 
''Reliability:''
 
''Validity:''
 
''Sensitivity and Specificity:''
 
''Minimally Detectable Change:''
 
'''Links'''
 
'''References'''
 
<span id="1320012004994S" style="display: none">&nbsp;</span>1.&nbsp; Shumway-Cook A, Brauer S, Woollacott M. Predicting the probability for falls in community-dwelling older adults using the timed up &amp; go test. Phys Ther. 2000;80(9):896-903.

Revision as of 00:03, 31 October 2011

Timed Up and Go Test (TUG)

Objective

To determine fall risk and measure progress of balance, sit to stand, and walking.

Intended Population This test was initially designed for elderly persons, but is used for people with Parkinsons, Multiple Sclerosis, hip fracture, Alzheimer, CVA, and others.

Method of Use The patient starts in a seated position, stands up upon therapist’s command, walks 3 meters, turns around, walks back to the chair and sits down. The time stops when the patient is seated. The subject is allowed to use an assistive device, and a practice trial should be completed before the timed trial. Be sure to document the assistive device used.

      Cut-off time for high risk of falls: Cut-off times to classify subjects as high risk for falling vary based on the study and

      participants. By using regression analysis Shumway-Cook used 14 seconds as the cut-off. Thus, if a subject took 14
      seconds or longer he or she was classified as high-risk for falling.1

       Materials Needed: one chair with armrest, stopwatch, tape (to mark 3 meters).

Evidence

Reliability:

Validity:

Sensitivity and Specificity:

Minimally Detectable Change:

Links

References

1.  Shumway-Cook A, Brauer S, Woollacott M. Predicting the probability for falls in community-dwelling older adults using the timed up & go test. Phys Ther. 2000;80(9):896-903.