Goniometry: Knee Extension: Difference between revisions
Claire Knott (talk | contribs) (Created page with "== Anatomical Movement == Knee extension == Testing position == Patient is in prone with test-side ankle off plinth and leg in extension. == Goniometer Placement == {| clas...") |
Claire Knott (talk | contribs) No edit summary |
||
Line 3: | Line 3: | ||
== Testing position == | == Testing position == | ||
Patient is in prone with test-side ankle off plinth | Patient is in prone with test-side ankle off plinth. | ||
== Goniometer Placement == | == Goniometer Placement == | ||
Line 17: | Line 17: | ||
== Expected Findings == | == Expected Findings == | ||
Expected range of motion in prone is | Expected range of motion in prone is 0 degrees and -5 degrees in females (hyper mobility) | ||
== References == | == References == |
Revision as of 12:46, 1 February 2019
Anatomical Movement[edit | edit source]
Knee extension
Testing position[edit | edit source]
Patient is in prone with test-side ankle off plinth.
Goniometer Placement[edit | edit source]
AXIS LOCATION | STATIONARY ARM | MOVEMENT ARM |
---|---|---|
lateral epicondyle of the femur | along the femur to the greater trochanter | along the fibula to lateral malleolus |
Expected Findings[edit | edit source]
Expected range of motion in prone is 0 degrees and -5 degrees in females (hyper mobility)